A patient with scoliosis and progressive deformity was admitted for posterior spinal fusion with instrumentation. A longitudinal incision along the length of the spine was made. The posterior elements of the spine were identified and prepared for fusion.
A Mazor X™ robot was attached to the patient to assist in the placement of bilateral pedicle screws from T5-T11. Fluoroscopy with O-Arm™ confirmed placement of the screws, and the wound was prepared for closure. What is/are the appropriate ICD-10-PCS code(s) for computer-assisted navigation with Mazor X™ robotic guidance?
Assign code 8E0W0CZ, Robotic assisted procedure of trunk region, open approach, for the Mazor X Stealth™ robotic assistance used during the posterior spinal fusion. This robotic system is used to ensure correct placement of the pedicle screws.
The information and opinions presented here are based on the experience, training, and interpretation of the author. Although the information has been researched and reviewed for accuracy, e4health does not accept any responsibility or liability regarding errors, omission, misuse, or misinterpretation. This information is intended as a guide; it should not be considered a legal/consulting opinion or advice.